• Features

     

    ·High power density design

    ·N+X parallel redundancy,support maximum 4 units in parallel

    ·Online double conversion with DSP control

    ·Input current harmonic: 3%

    ·Wide input voltage range: 208~478Vac

    ·Wide input frequency range 40~70Hz

    ·Optimization battery group, the quantity of battery

    ·Maximum charging current up to 18A (Settable)

    ·TFT LCD display

    ·Versatile LCD human-computer interface

    ·Generator compatible

    ·ECO mode operation for energy saving

    ·Self-testing when UPS startup

    ·50/60Hz frequency converter mode

    ·Cold start

    ·The output can meet 100% unbalanced load

    ·Multiple protection function: short-circuit, overload, overheat,   battery overcharge and overdischarge, output low voltage    and fan fault alarm

    ·Multiple communication interface: USB, RS232, RS485,

    -Parallel port, Dry contact, Intelligent slot, SNMP card    (Optional), Relay card (Optional), Battery temperature    sensor (Optional)

     

Cabacity

20 KVA  / 20KW

INPUT

 

Nominal voltage 

380/400/415Vac (3Ph+N+PE)

Operating voltage range

305~478Vac (Full load); 208~478Vac (50% load)

Frequency range

40~70Hz (50/60Hz Auto-Sensing) 

Power factor

≥0.99

Bypass voltage range

Max.voltage: 220V: +25% (Optional +10%, +15%, +20%) 230V: +20% (Optional +10%, +15%)
240V: +15% (Optional +10%)
Min.voltage: -45% (Optional -20%, -30%)

Frequency protection range

50/60Hz±10% 

ECO range 

Same as bypass

Harmonic distortion (THDi)

≤3% Linear load

OUTPUT

 

Output voltage

380/400/415Vac (3Ph+N+PE)

Power factor

1

Voltage regulation 

±1%

Output
frequency

Line Mode :±1%/±2%/±4%/±5%/±10% of the rated frequency
Bat. Mode :(50/60±0.1%)Hz

Crest factor

3:1

Harmonic distortion (THDv)

≤2% Linear load
≤5% Non linear load

Transfer time

0ms

Output waveform

Pure Sinewave

Overload 

AC Mode : Load≤110%: last 60min turn to bypass; ≤125%: last 10min  turn to bypass;≤150%: last 1min  turn to bypass; ≥150% turn to bypass mode immediately Bat.Mode : Load≤110%: last 10min; ≤125%: last 1min; ≤150%: last 5s; ≥150%: shut down UPS immediately

EFFICENCY

 

EFFICENCY

94.5%

BATTERIES

 

Battery voltage

±180/192/204/216/228/240/252/264/276/288/300Vdc (30/32/34/36/38/40/42/44/46/48/50pcs supportable)

Charging current (Max)

18A (Max.)

INDICATORS

 

LCD display

Input voltage,Input frequency,Output voltage,Output frequency,Load percentage, Battery voltage,Inner temperature& Remaining battery backup time

ALARM

 

Battery mode

Beeping every 4 seconds

Low Battery 

Beeping every second

Overload 

Beeping twice every second

Fault

Continously beeping

ENVIRONMENT

 

Operating temperature

0℃~40℃

Storage temperature

-25℃~55℃

Humidity range

20~95%RH @ 0~40℃ (Non condensing)

Altitude

<1500m,derating required when>1500m

Noise level

<58dB at 1 Meter

STANDARDS

 

Safety

IEC/EN62040-1,IEC/EN62477-1

EMC

IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8