Titanium Peta Power 10 kva online RT
- ·High power density
·LCD supports Rack/Tower convertible design
·N+X parallel redundancy, support maximum 4 units in parallel
·Online double conversion with full digital control
·Optimization battery group, the quantity of battery: 16/18/20pcs (Settable)
·Wide input voltage range: 110~286Vac
·Wide input frequency range
·Generator compatible
·ECO mode operation for energy saving
·Self-testing when UPS startup
·Multiple communication interface: RS232/USB/PO (Relay card /SNMP card optional)
·Parallel kit default
·Maximum charging current up to 10A
·Cold start
·Intelligent fan speed regulation
·Multiple protection function: short-circuit, overload, overheat, battery
. overcharge and overdischarge, output low voltage and fan fault alarm
MODEL | Titanium PETA POWER 10 KVA RT ONLINE 1/1 |
Cabacity | 10 KVA / 10000 W |
INPUT |
|
Nominal voltage | 208/220/230/240Vac |
Input voltage range | 110~286Vac |
Frequency range | 40~70Hz (50/60Hz Auto-Sensing) |
Bypass voltage range | Max.voltage: 220V: +25% (Optional +10%, +15%, +20%) 230V: +20% (Optional +10%, +15%) |
Power factor | ≥0.99 |
OUTPUT |
|
Output voltage | 208/220/230/240Vac |
Power factor | 1 |
Voltage regulation | ±1% |
Output | Line Mode :4±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) |
Crest factor | 3:1 |
Harmonic distortion (THDv) | ≤2% Linear load |
Transfer time | AC mode to Bat.mode :0ms / Inverter to Bypass :0ms |
Output waveform | Pure Sinewave |
EFFICENCY | UP TO 94 % |
OVER LOAD | line mode : Load≤110% last 60min; ≤125% last 10min; ≤150% last 1min; >150% turn to bypass mode immediately Bypass Mode : 63A (Breaker ) |
|
|
BATTERIES |
|
Battery voltage | ±96/±108/±120Vdc (Settable) |
Typical recharging time | 6~8 hours (To 90% of full capacity) |
Charging current (Max) | Max.current 10A (Charging current can be set according to battery capacity) |
INDICATORS |
|
LCD display | Input voltage,Input frequency,Output voltage,Output frequency,Load percentage, Battery voltage,Inner temperature& Remaining battery backup time |
ALARM |
|
Battery mode | Beeping every 4 seconds |
Low Battery | Beeping every second |
Overload | Beeping twice every second |
Fault | Continously beeping |
ENVIRONMENT |
|
Operating temperature | 0℃~40℃ |
Storage temperature | -25℃~55℃ |
Humidity range | 20~95%RH @ 0~40℃ (Non condensing) |
Altitude | <1500m,derating required when>1500m |
Noise level | <58dB at 1 Meter |
STANDARDS |
|
Safety | IEC/EN62040-1,IEC/EN62477-1 |
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |
PHYSICAL |
|
Dimension W x D×H (mm) | 440×625×86.5.5 |
Net weight (kg) | 18 |
Specifcaions are Subject to change without prior notice |